The purpose of this experiment is to show the characteristics of the boiling phase change concept.

Order ready-to-submit essays. No Plagiarism Guarantee!

Note:  All our papers are written from scratch by human writers to ensure authenticity and originality.

Abstract

Check your essay before you submit. See exactly what your professor sees.

See your AI and plagiarism results before your instructor does.Get the exact same report your professor uses. Trusted by 50,000+ students worldwide.

The purpose of this experiment is to show the characteristics of the boiling phase change concept. The regions include free convection, nucleate, transition, and film boiling.

The experimental value for maximum heat flux has been calculated to be 1244 W/m^2 and the theoretical value is 137090 W/m^2. This yields a percentage error of 99.1 % which is considered high. From the curves we can see that temperature decreases incrementally as time passes.

The large error in the calculation of the values for the heat flux can be explained by having started the DAQ software before placing the sphere into the liquid nitrogen cylinder and this time was not identical for both spheres. Another possible area of error is the measurement of the diameter of the spheres and it is a very crucial measurement as if affects Volume, Area and the diameter that are all part of important results. Doing several runs of measuring the diameters and averaging it might have yielded better experimental results.

Outline Lab Procedure

1. Measure the diameters of the two spheres.

2. A dewar is filled with liquid nitrogen upto one third of its volume and has two thermocouples attached to it.

3. Choose one of the spheres to have it quenched in a bath of liquid nitrogen.

4, Setup and configure the data acquisition software.

5. Click the manual trigger button on the DAQ prior to inserting the sphere into the dewar of liquid nitrogen and also click the start button to monitor the changes in temperature.

6. Observe the boling phenomenon that occurs in the transient period.

7. Stop the data acquisition software once the minimum temperature has been reached.

8. Remove the sphere from the liquid nitrogen dewar and place it in a dewar filled with water and observe.

9. Data will be automatically exported to Excel and Columns B and C correspond to the temperatures of the two thermocouples.

10. Repeat the experiment for the other sphere.

11. Since this is a short experiment in terms of time duration, do it multiple times to ensure accuracy of results.

Discussion

1. The two spheres can be considered identical in terms of geometry and physical properties, yet the only difference is the size. Radial temperature is affected by the sphere’s size. We have chosen to consider the small sphere because it is less affected in terms of the radial temperature and the lumped capacitance is more applicable for the analysis to be performed.

5. We have seen from the results that the last 8 data points have the Bitot Number exceeding 0.1 which may have caused invalidity with the requirement of the lumped capacitance method for the Bitot Number to be below 0.1.

12.

a. The percentage error in the calculation for the maximum heat flux shows a very large experimental or arithmetic error which is around 99.1%.

b. The boing curve is difficult to construct as choosing the end points for t* and t** is a time consuming process and each change in the end point affects each curve fitted graph and hence changes the equations and the derivatives. The slopes have to match in order to ensure that the curve is ideal and this takes some time.

c. The time constant to reach 40 degrees Celsius for the natural convection cooling experiment was calculated to be around 1975 seconds. In our case the time constant is much smaller and this can be explained since the rate of heat transfer at boiling is much higher than that of convection.

d. The transient cooling rate was an interesting concept and visually observing the sphere as bubbles of vapor cover it and the heat transfer rate has decreased since there is less surface contact.

e. The lumped capacitance method is valid for the entire data points except the last 8 data points where the Biot number exceeded 0.1.

f. The calculated value for the minimum heat flux is 4364 W/m^2

h. The different boiling regimes are similar to the theoretical boiling curve, the large error in the experimentally determined value for the maximum heat flux may have affected the results, but overall the shape is similar to the theoretical curve.

Discussion:

The accuracy of our experimental results were not nearly as good as expected when it came to our boiling curve. Our inaccuracies with our boiling curve could be due to our polynomial curve fits that are not the best approximation for our Temperature vs time curve. Our difficulty when constructing the boiling curve arose when trying to utilize the polynomial curve fits for our calculations of dTs/dt. It can be seen that there are sharp changes at each point where a curve fit transitioned to the next polynomial. One way to improve this would be to increase the order of the polynomial to get a more accurate fit.

This experiment took few minutes to reach steady state temperature as the sphere was cooled down with liquid nitrogen. It can be seen that there is a noticeable change in heat flux due to the values of dTs/dt . There were also points where the lumped capacitance were not valid as the Bi number was higher than 0.1 and that results on lumped capacitance reaching the state of being invalid.